The various modules were developed in a MATLAB/ Simulink environment and auto code generation was done using TargetLink. The various modules implemented by Tata Elxsi included relay handler, SSSW handler, diagnostic DTC, safeRAM handler etc.
Scope of Engagement
- Study of the specification
- Modeling in Matlab /Simulink of the modules
- Review of the models
- Preparing Unit test cases and review
- Unit testing of the models
- Model in loop testing
- Data dictionary preparation and Auto code generation
- Software in loop testing
Tata Elxsi’s Value Proposition
- Tata Elxsi’s strong understanding of supplier development process, standards and diagnostics requirements
- Tata Elxsi’s strong expertise in Model-based design enabled the customer to reuse the software modules across different multiple platforms
- Capability to generate production code generation directly from Simulink®/Stateflow, by established and well defined autocode methodologies